Profile-based LECO ChromaTOF 5.x SMP files with mass spectra can now be imported, in addition to the PEG-based and signal-based SMP files already supported. Previously, profile-based SMP files with mass spectra were rejected as unsupported.
Mass spectra are binned to nominal masses with bin boundaries at −0.3 and +0.7 (for example, m/z 99.7 to 100.7 for nominal mass 100), so they closely match a ChromaTOF netCDF export of the same run.
Import of Shimadzu .lcd files has been updated:
Compatibility:
At startup, the software now locates the NIST MS Search installation more reliably when several NIST versions are installed or a version was recently removed. The latest full version is preferred.
Also, in NIST Search Settings:
Integrated spectra of blobs, binned according to MS Data Binning, are now computed and displayed with improved performance.
In List Operations and the Journal, operations that are undone together as a single step are now grouped under one expandable row, making the operation history easier to read. Searching with the Find bar also finds operations inside collapsed groups.
Clear Metadata now opens a dialog for choosing which types of metadata to remove from the image: Blob metadata, Graphics, Text objects, Chemical structures, Template objects, and Blob exclusions. Template objects and Blob exclusions are off by default.
Clear Metadata is now available as Edit > Clear Metadata..., in addition to the toolbar button. If the metadata came from the most recent change, the dialog suggests undoing that step and offers a shortcut to List Operations.
Compatibility: Excluded blobs are now restored only when the Blob exclusions option is selected. Previously, Clear Metadata always restored all excluded blobs.
Deleting or excluding a large selection of blobs, such as all blobs of an image with many detected peaks, is now much faster with Edit > Delete/Exclude (and its toolbar button) and with Edit > Exclude Blobs in Shape. Undoing these operations is also much faster.
Text objects, the metadata legend, and axis labels now display characters that the selected font cannot render, such as Chinese characters, on screen and in exported pictures. Previously, these characters were shown as empty boxes unless a font that supports them was selected. Some characters may require installing a font that supports them.
Shift Phase to Reference now remembers the most recently used reference image and regions, even after the software is closed and reopened. When browsing for the reference image, Recent and Default shortcuts open the folder of the last reference image or of the current image. If the reference image cannot be opened, for example because it was moved, an error message now explains why.
A new Clear Metadata method command removes metadata from the image during a method. It offers the same choices as the interactive Clear Metadata dialog. By default, blob exclusions and template objects are kept.
In the Overlay View of Compare Images, the Flicker and Transparent displays are merged into a single Blend display, which is now the default. Blend provides:
The Raw Difference and Raw Fuzzy Difference displays are unchanged.
Compare Images can now compare images that have no blobs. When the analyzed or reference image has no blobs, blobs are detected automatically with the current blob detection settings, and the image itself is left unchanged. The image is marked auto-detected blobs, and its blob IDs are shown as *.
The new Preprocessing > Auto detect option, in the new Options panel of the dialog for choosing the reference image, turns this on or off and limits the number of blobs detected. It is on by default, with a limit of 10000 blobs.
A new Compare > Only use peak spectra option, in the Options panel of the dialog for choosing the reference image for Compare Images, compares compounds by their peak spectra. Comparisons open much faster because integrated spectra are not loaded. The option is on by default; when it is off, the default spectrum type from the system settings is used, as in previous versions.
Matching all blobs between the analyzed and reference images in Compare Images is now faster. The improvement is largest for images with many blobs.
The file chooser of Import Files has been improved:
If the Amount Unit of the Amount Table contained characters such as &, <, or >, the saved image file could not be opened again. These characters are now saved correctly.
Importing Shimadzu .gcd and .lcd files requires the Microsoft Visual C++ v14 (x64) runtime, which the installer did not include. On computers without it, the import failed with an unclear error. The installer now offers Install MVC++ v14 (x64), selected by default for new installations, and the import reports when the runtime is missing or out of date.
After excluding a blob and then undoing the exclusion, the Nearest Blob column of other blobs could keep pointing to a different blob instead of returning to its original value. This also happened near the edge of an image that had been phase shifted.
Shift Phase to Reference could determine a wrong shift, or none, when the current and reference images started at different first-dimension times, for example when one of them had been cropped.
If the current or the reference image does not cover the full modulation period in the second dimension, for example because it was cropped, Shift Phase to Reference now stops with an unsupported error and no shift is applied. If the modulation of the reference image does not match that of the current image, it stops with an incompatible error.
Entering a distance threshold of 1000 or more in the Match Remaining options caused an error, and the value could not be used.
A logic error in Match Using Reference has been corrected. In some cases where expected peaks were not detected in the current image, this error caused template peaks to be matched to neighboring blobs.
In the quantification settings of a calibration table, a very small Default Response Factor (for example, 0.000009) was shown as 0, although the entered value was still used to compute amounts. The value is now displayed as entered.
When uncalibrated compounds were set to use Nearest Neighbor and no suitable calibrant was found, no amount was computed. The Default Response Factor is now used in this case, as described in the quantification settings.
Importing an RI table from Configure > RI Table failed with an error when the file was in a folder whose name contained non-ASCII characters, such as GC×GC.
On a computer without a NIST MS Search library, clicking OK or Apply in Configure > Settings reported that the included library list was empty, and none of the settings were applied. In addition, a library search without NIST installed now reports the problem instead of failing without a message.
Auto Locate could fail to find some NIST 26 demo installations, such as the tandem MS demo.
In version 2026R1, with the Windows look and feel selected, resizing a window could leave leftover background artifacts in the newly exposed area.
On some Windows systems, a project with a very long name or path that was opened by browsing for it could fail with an error when processing runs.
After selecting a file and then navigating to another folder, the Import Files file chooser could close without a valid file to import.
Creating a project with the New Project wizard reported errors when none of the recently used project folders existed anymore. The wizard now starts in the default folder.
With Ignore file extension selected, Create Sequence Table from Runs reported an uncaught exception when the name of a run file ended with a space just before the extension, for example Sample 01 .smp.
When images were loaded into Investigator with a feature template, blobs that had been excluded in the images, such as column bleed or solvent front, were restored. They now stay excluded.
When an amount is computed with the Default Response Factor, the Amount Source column of the Blob Table now shows the response factor in parentheses with 6 decimal places.
Compatibility: Scripts or tools that parse the Amount Source column of exported blob tables or reports must be updated for the new format.
This release includes the Java 11.0.33+10 runtime (Azul Zulu 11.92.113) and security updates for other third-party components.
For information on the security content of this update, contact support@gcimage.com.